MAINTENANCE BLEEDING AIR FROM FUEL SYSTEM Manual bleeding will be required if: l The fuel filter is not filled prior to installation. 0 Injection pump is replaced. l High pressure fuel lines are replaced. Venting the low pressure lines and fuel filter 1. Loosen bleed screw (1). 2. Operate hand lever (2) until the fuel flowing from the fiiing is free of air. Tighten bleed screw (1) to 0.82 kgm. Venting at the injection pump 1 1. Air can be vented from the injection pump through the fuel drain manifold line by operating the starting motor. 9 When using the starting motor to vent the system, do not engage it for more than 30 seconds at a time: wait two minutes between engagements. * WARNING!
It is necessary to put the engine in the “RUN” position. Because the engine may start, be sure to follow all the safety precautions. Use the normal engine starting procedure. A LilAJOZ! 1= OFF B = ON C = START 3-7