MAINTENANCE COOLING SYSTEM COOLANT RECOMMENDATIONS / SPECIFICATIONS For coolant recommendations / specifications, refer to “COOLANT” under “LUBRICANTS, FUEL AND COOLANT”. CHANGING COOLANT AND FLUSHING SYSTEM * Stop the machine on level ground when cleaning or changing the coolant. * The antifreeze/DCA4 mixture must be changed every two years. * Use antifreeze during all seasons to protect the cooling system from corrosion as well as freezing damage. * In tropical climates where antifreeze availability may be limited, use a corrosion inhibitor (Cummins liquid DCA), or an equivalent to protect the engine cooling system.
* A mixture of 50% water and 50% ethylene-glycol base antifreeze is required for operation of the engine in temperature environments above -37°C. * Do not operate the engine without a thermostat. 1. Stop the engine. * Check for damaged hoses and loose or damaged hose clamps. Replace as required. Check the radiator for leaks, damage and build up of dirt. Clean and repair as required. 2. Turn cap (1) slowly until it comes off. A WARNING! Do not remove cap (1) while coolant is hot. Hot coolant may spout out. When removing radiator cap, lift the lever to relieve innerpressure.
U)6AM03d Open drain valve (2) at the bottom of the radiator and plug (3) in the bottom of the water inlet on the engine side to drain off the coolant. Drain off all the water, then close up drain valve (2), plug (3), and pour in soft water (ex: city water) up to the vicinity of the water filler. When the water reaches the vicinity of the water filler, put the engine at low idling, open drain valve (2), plug (3), then pass water through the cooling system for 10 minutes. * When doing this, adjust the inflow and oufflow of water so that the radiator is always full. 3-57