Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

EPA07 MBE 4000 SERVICE MANUAL 5. Check the valve lift on the intake valves. See Figure 1-124. Listed in Table 1-36 are the specifications. 1. Dial Gauge 4. Pushrod 2. Gauge Holder 5. Intake Valve 3. Intake Rocker Arm Figure 1-124 Checking Valve Lift, Intake Valves Table 1-36 Valve Lift Specifications [a] Mount a dial gauge and a gauge holder on the valve bridge. Mount the dial gauge with a preload of approximately 15 mm (0.60 in.) to provide adequate travel for checking the intake valve lift. [b] Set the scale on the dial gauge to "0" (zero). [c] Using the engine barring tool (J–46392), rotate the flywheel in a counterclockwise direction (as viewed from the flywheel end). NOTE:

The dial gauge will show the highest reading when the valve is completely open. All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 1-139 Description Specification mm (in.) Specified Dial Gauge Preload for Checking Valve Lift 15 (0.60) Valve Lift with Intake Valves Completely Open 11.546 (at least 0.4546) Valve Lift with Exhaust Valves Completely Open 11.963 (at least 0.4710)