1.20 VALVES [d] When the intake valves are completely open, read off the value on the dial gauge. If the intake valve lift reaches at least 11.546 mm (0.4546 in.) at its highest point, the intake valves are lifting correctly. If the intake valve lift fails to reach 11.546 mm (0.4546 in.) at its highest point, remove the camshaft and inspect the cams for wear. Refer to section 1.22.1. NOTE: If the gauge reading fails to reach 11.546 mm (0.4546 inch), be sure the valves were completely open. The dial gauge will show the highest reading when the valve is completely open. 6. Check the lift on the exhaust valves. See Figure 1-125. 1. Dial Gauge 4. Pushrod 2. Gauge Holder 5. Exhaust Valve 3.
Exhaust Rocker Arm Figure 1-125 Checking Exhaust Valve Lift [a] Turn the flywheel in a counterclockwise direction until both exhaust valves are closed. [b] Move the dial gauge and gauge holder to the spring retainer on the exhaust valve. Make sure the dial gauge still has a preload of approximately 15 mm (0.60 in.) to provide adequate travel for checking the exhaust valve lift. [c] Set the scale on the dial gauge to "0" (zero). [d] Using the engine barring tool, (J–46392) turn the flywheel in a counterclockwise direction (as viewed from the flywheel end). NOTE: The dial gauge will show the highest reading when the valve is completely open. All information subject to change without notice.
1-140 DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION