Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

EPA07 MBE 4000 SERVICE MANUAL [e] When the exhaust valve is completely open, read off the value on the dial gauge. If the exhaust valve lift reaches at least 11.963 mm (0.4710 in.) at its highest point, the exhaust valve is lifting correctly. If the exhaust valve lift fails to reach 11.963 mm (0.4710 in.) at its highest point, remove the camshaft and inspect the cams for wear. Refer to section 1.22.1. NOTE: If the gauge reading fails to reach 11.963 mm (0.4710 in.), be sure the valves were completely open. The dial gauge will show the highest reading when the valve is completely open. 7.

Check the valve lift, both intake and exhaust, on the remaining cylinders, one at a time, until all have been checked. 8. Remove the dial gauge and holder from the cylinder head. 9. Check and adjust the valves. Refer to section 13.1. 10. Remove the engine barring tool (J–46392) from the flywheel housing and install the inspection cover. Tighten the inspection cover bolts 25 N·m (18 lb·ft). 11. Install the cylinder head cover(s). Refer to section 1.2.2. 1.20.2 Measurement of Valve Head Recess Depth Measurement steps are as follows: 1. Remove the cylinder head from the engine. Refer to section 1.3.1. All information subject to change without notice.

DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 1-141