Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

EPA07 MBE 4000 SERVICE MANUAL 1. Using a dial caliper, measure the length of the M10 tensioning arm bolt from the end of the bolt to the bottom of the flange. See Figure 2-25. The acceptable lengths are listed in Table 2-1. Replace any bolt which does not meet these specifications. 1. Dial Caliper 3. Bottom of Flange 2. End of Tensioning Arm Bolt Figure 2-25 Tensioning Arm Bolt Table 2-1 Specifications for M10 Tensioning Arm Bolt All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 2-37 Description Length, mm (in.) Shaft length when new 90.0 (3.54) Maximum shaft length 91.0 (3.58)