Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

EPA07 MBE 4000 SERVICE MANUAL 2. Disconnect the fuel doser supply line from the fuel doser injector valve. Hold the injector valve with a wrench when loosening the line fitting. 3. Disconnect the lines for coolant in and coolant out from the doser housing. 4. Loosen two bolts and remove the fuel doser housing from the exhaust pipe. 2.15.4 Installation of the Fuel Doser Housing Install as follows: 1. Install the fuel doser housing to the exhaust pipe with two bolts. Torque the bolts to 34 N·m (25 lb·ft). 2. Connect the coolant feed and return lines using new seal rings. Torque the banjo bolts to 15 N·m (11 lb·ft). 3. Connect the fuel doser supply line to the fuel doser injector valve.

Hold the fuel doser injector valve with a wrench while torquing. Torque to 16-20 N·m (12-14 lb·ft). 4. Install the protective cover (if equipped). ENGINE EXHAUST To avoid injury from inhaling engine exhaust, always operate the engine in a well-ventilated area. Engine exhaust is toxic. 5. Fill the cooling system. 6. Start the engine. NOTE: It may take more than one purge attempt to completely purge all of the air from the fuel line. 7. Using DDDL 7.X, command the Purge function. 8. Check for exhaust leaks. 9. Shut off the engine. All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 2-65