EPA07 MBE 4000 SERVICE MANUAL 6. Using a dial gauge, measure the end play of the pump drive gear and idler gear against the walls of the pump housing. See Figure 3-17 for set-up and listed in Table 3-2 are the specifications. 1. Dial Gauge 3. Oil Pump 2. Support Figure 3-17 Measuring the Clearance of the Pump Drive Gears [a] Secure the assembled oil pump in a vise, with the face plate pointing up. [b] Rest the dial gauge support on the face plate. [c] Set up the dial gauge so that the feeler on the end of the gauge touches the exposed end of the pump drive gear with some preload. [d] Force the pump drive gear downward as far as it will go.
[e] At this position, adjust the scale of the dial gauge to "0" (zero). [f] Now force the pump drive gear upward as far as it will go. Read the measurement on the dial gauge and make sure it conforms to the range listed in Table 3-2. Replace the pump, if necessary. [g] Repeat this procedure for the idler gear. 7. Install the oil pump in the cylinder block. Refer to section 3.5.4. 3.5.4 Installation of Oil Pump and Sump Pipe Installation steps are as follows: 1. Coat the contact surface between the block and the oil pump with Loctite® 574. All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 3-19