EPA07 MBE 4000 SERVICE MANUAL 3.7.1.1 Testing of Oil Cooler Element Pressure Testing steps are as follows: 1. Regulator Valve 4. Pressure Hose 2. Shutoff Valve 5. Oil Cooler Element 3. Regulator and Gauge Figure 3-23 Pressure Checking the Oil Cooler Element 1. Install the air supply test adapter to one of the oil passages on the oil cooler element. See Figure 3-23. 2. Install test adapter plug to the opposite oil passage. See Figure 3-23. 3. Using the existing bolts from the oil cooler cover attach the safety straps. See Figure 3-23. 4. Connect pressure hose to the pressure regulator (J-45982-7). See Figure 3-23. 5.
Check and ensure that the shutoff valve is in the OFF position and connect shop air to the pressure regulator. 6. Set the regulator pressure to zero by pulling up on the adjusting knob and turning counterclockwise until its stops. 7. Turn shutoff valve to the ON position. 8. Adjust system pressure by pulling up on the adjusting knob and turn clockwise until pressure reading on gauge is 344 kPa (50 psi). NOTE: DO NOT connect pressure hose (J-47313-2) to air supply fitting on the oil cooler until the pressure regulator has been adjusted to 344 kPa (50 psi). All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 3-27