Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

3.7 OIL COOLER/FILTER HOUSING To avoid injury from flying debris, wear a face shield or goggles. EYE INJURY 9. Once the pressure regulator has been adjusted, connect the pressure hose to air supply fitting on the oil cooler element. BURNS To avoid injury from burning, use lifting tools and heat-resistant gloves when handling heated components. 10. Submerge the oil cooler element completely in a hot water tank. Leave the element submerged for five minutes. 11. In the event of failed oil cooler element, a steady stream of air bubbles will come out of the oil cooler. Replace the element. NOTE: Some leakage may occur from the J-47402 fittings. Do not mistake this for a leaking oil cooler element.

12. If the oil cooler element shows no signs of leakage, inspect the sealing surfaces and conditions of each gasket. 13. Remove the oil cooler test kit components from the oil cooler element. 3.7.2 Installation of Oil Cooler/Filter Housing Install the oil cooler/filter housing as follows: 1. Check the oil cooler element and the inside of the cooler housing for corrosion, contamination by metal particles, or abrasive material, such as sand. [a] If corrosion is found, clean or replace the oil cooler, as necessary. [b] Clean the mating surfaces of the oil cooler element and cooler housing. Remove any bits of adhering gasket material. 2.

Install the oil cooler element and new gaskets on the heat cooler/filter housing. Tighten the element bolts to 25 N·m (18 lb·ft). All information subject to change without notice. 3-28 DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION