EPA07 MBE 4000 SERVICE MANUAL PERSONAL INJURY To avoid injury from hot surfaces, wear protective gloves, or allow engine to cool before removing any component. [a] Measure the water temperature. As the temperature climbs to around 75°C (167°F), slow the rate of heating down to about 1-2°C (2-3°F) per minute. [b] In about five minutes, the main valve should begin to open. 4. Continue to heat the water at this rate for about six to eight minutes until it reaches the opening temperature of the main valve. If the main valve is not completely open, replace the thermostat. See Figure 4-12. 1. Thermostat 2. Main Valve 3. Short Circuit Valve Figure 4-12 Thermostat Lift 5.

Check all the test values for the main valve listed in Table 4-5. If any of the values is not met, replace the thermostat. Table 4-5 Thermostat Test Values All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 4-21 Description Temperature °C (°F) Distance mm (in.) Main Valve Starts To Open 81-85 (177-185) — Main Valve Fully Open 95 (203) — Main Valve Minimum Lift — 8 (0.3) Short Circuit Valve Fully Closed 92° (198) — Short Circuit Valve Minimum Lift — 6-7.5 mm (0.24-0.295 in.)