Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

4.4 THERMOSTAT [a] At the temperature of 85°C (185°F), check that the main valve has started to open. [b] At the opening temperature of 95°C (203°F), check that the main valve is fully open. [c] Check the minimum lift of the main valve at the opening temperature. 6. Check all the test values for the short circuit valve listed in Table 4-5. If any of the values is not met, replace the thermostat. [a] At the temperature of 92°C (198°F), check that the short circuit valve is fully closed. [b] Check the minimum lift of the short circuit valve at the closing temperature. 7.

Install the original or replacement thermostat(s), as necessary, the upper coolant hose inlet, and seal ring(s) on the coolant pump, as removed. 8. Fill the engine with coolant, as removed, and check for leaks and proper operation. 4.4.2 Installation of Thermostat Installation steps are as follows: 1. Install a new seal ring on each thermostat. 2. Install the original and/or replacement thermostats. 3. Install the thermostat housing. Install the mounting bolts attaching the thermostat housing to the coolant pump housing. Tighten each mounting bolt to 25 N·m (18 lb·ft). See Figure 4-10. 4. Install the upper coolant tube on the thermostat housing. Tighten the hose clamp until firm. 5.

Fill the engine with coolant, and check for leaks and proper operation. Refer to section 4.1.1. All information subject to change without notice. 4-22 DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION