Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

6.3 GAS MIXER HOUSING 9. Remove two bolts mounting the EGR gas outlet pipe to the gas mixer housing. See Figure 6-5. 10. Remove two bolts (M8 x 16mm) attaching the mounting bracket on the EGR gas outlet pipe to the air intake manifold. Move pipe away from mixer housing. See Figure 6-5. 11. Remove two bolts (Extreme Cold Climate EC2 - M10 x 25mm) (Non EC2 - M8 x 25mm) attaching the mixer housing to the air intake manifold and remove the housing and gasket. Discard the gasket. See Figure 6-5. 12. If necessary, remove the mixer tube and gasket from the mixer housing. See Figure 6-5. 6.3.2 Installation of Gas Mixer Housing Installation steps are as follows: 1.

Install a new gasket and position the gas mixer housing over the four studs on the air intake manifold. Secure the housing to the manifold with two bolts. See Figure 6-5. [a] Extreme Cold Climate (EC2) M10 x 25mm, torque the bolts to 60 N·m (44 lb·ft). [b] Non-EC2 M8 x 25mm, torque the bolts to 25 N·m (18 lb·ft). 2. Attach the EGR gas outlet pipe and gasket to the mixer housing with two bolts. Torque the bolts to 35 N·m (26 lb·ft). See Figure 6-5. 3. Install two bolts (M8 x 16mm) and secure the mounting bracket on the EGR gas outlet pipe to the air intake manifold. Torque the bolts to 25 N·m (18 lb·ft). See Figure 6-5. 4.

Install the gasket, elbow, throttle valve and adaptor as an assembly over the four studs on the air intake manifold. Secure the assembly to the air intake manifold with four locking nuts. Torque the nuts to 50 N·m (37 lb·ft). See Figure 6-5. 5. For engines equipped with the Extreme Cold Climate (EC2) Package, install the coolant feed line to the intake throttle valve. 6. Connect the electrical connector to the air intake throttle valve. 7. Connect the electrical connector to the intake air temperature/pressure sensor on the top of the mixer housing. 8. If equipped with a grid heater connect harness connector and electrical connections. 9.

Connect the charge air hose connection to the intake throttle adaptor. Tighten the clamps securely. All information subject to change without notice. 6-12 DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION