6.4 AIR INTAKE MANIFOLD 3. Install the intake air temperature/pressure sensor in the gas mixer housing. Refer to section 6.6.2. 4. Connect the electrical connector to the air temperature sensor on the gas mixer housing. 5. Install the EGR gas mixer housing. Refer to section 8.7.2. 6. Install the engine trim cover side panels. Refer to section 1.1.2. 7. Lower the hood and remove the chocks from the rear tires. 6.4.3 Removal of Crankcase Breather Pipe Removal steps are as follows: 1. Air Intake Manifold 5. Bolts (qty 3) 2. Electrostatic Oil Separator 6. Crankcase Breather Pipe 3. Bracket (Upper) 7. Retaining Clamps (qty 6) 4. Seal Ring 8. Bracket (Lower) Figure 6-6 Crankcase Breather Pipe 1.

Remove the crankcase breather pipe from the electrostatic oil separator by compressing the band at the connection and pulling outward. Remove and discard the seal ring on the separator. See Figure 6-6. 2. Remove the bolt and nut at clamp and release pipe from hose bracket, then remove the pipe. See Figure 6-6. All information subject to change without notice. 6-14 DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION