Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

EPA07 MBE 4000 SERVICE MANUAL 6.4.4 Installation of Crankcase Breather Pipe Installation steps are as follows: 1. Install a new seal ring on the electrostatic oil separator, then connect the breather pipe to the separator by snapping into place. See Figure 6-6. 2. Secure the crankcase breather pipe with the hose bracket and a bolt (M8 x 25)and nut at the clamp. Torque the bolt and nut to 25 N·m (18 lb·ft). See Figure 6-6. All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 6-15