EPA07 MBE 4000 SERVICE MANUAL Electrical Shock Hazard High voltage can remain inside the Electrostatic Oil Separator after removal. Wait 30 minutes after turning off the ignition before removing the separator. Never touch parts through ventilation openings or impeller opening with finger or conductive items (e.g. screwdriver or wire). High voltage can remain inside the Electrostatic Oil Separator for up to 12 hours after the ignition is turned off. 3. Remove two bolts securing the oil separator to the air intake manifold. Carefully pry the end cover and oil separator from the air intake manifold and remove separator. See Figure 6-7. 4.

Never touch parts through the ventilation openings or impeller end with fingers or conductive items e.g. screwdriver or wire. The separator can contain high voltage for up to 12 hours. See Figure 6-8. 1. Ventilation Openings 2. Impeller Opening Figure 6-8 Electrostatic Oil Separator Electrical Shock Hazard 5. Inspect the two isolator rings and seal rings on the electrostatic oil separator. Discard the isolators and seal rings if damaged. 6. Remove the seal ring from the pressure regulator valve and discard the seal ring. All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 6-17