Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

6.8 WASTEGATE ACTUATOR 6. Remove the adjusting rod and jam nut from the actuator swing-arm pin. NOTE: There is significant tension on the actuator rod and swing arm. Take care no to damage the swing arm pin when removing the adjusting rod. 7. Remove the adjusting rod and jam nut from the actuator rod. 8. Remove the actuator and heat shield from the mounting bracket. 6.8.2 Verification of Wastegate Actuator Operation With the actuator disconnected from the turbocharger, it is possible to verify proper operation of the wastegate actuator. Due to the internal preload of the actuator return spring, movement of the actuator rod may not be seen at low pressures. 1.

Connect regulated shop air to the wastegate actuator. 2. Slowly increase the regulated air pressure from 0 to 45 psi (0 to 300 kPa). 3. Verify that the wastegate actuator rod moves from the fully relaxed position to the fully extended position. 4. Using a soapy water solution, spray the wastegate actuator and check for leaks. No bubbles should be seen around the actuator body. 5. Slowly reduce air pressure from 45 to 0 psi (300 to 0 kPa). 6. Verify that the wastegate actuator rod moves from the fully extended position to the fully relaxed position. 6.8.3 Installation and Adjustment of Wastegate Actuator Installation is as follows: NOTE:

Proper installation and adjustment of the wastegate actuator requires the use of a highly accurate digital air pressure gauge, TLZ00101 or equivalent. 1. With the adjusting rod and jam nut removed from the actuator rod, install the heat shield on the new wastegate actuator, and then install the wastegate actuator to the actuator bracket. Tighten nuts to 12 N·m (9 lb·ft). 2. Thread the jam nut and adjusting rod onto the actuator rod; do not tighten. 3. Attach regulated shop air to the digital pressure/regulator setup. 4. Adjust the regulator output knob until airflow stops. 5. Turn the digital pressure gauge (TLZ00101 or equivalent) on and set to “zero.” 6.

Attach the digital pressure/regulator hose to the wastegate actuator port. All information subject to change without notice. 6-36 DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION