EPA07 MBE 4000 SERVICE MANUAL 7. Connect the new wastegate actuator to a regulated air supply as shown in Figure 6-20. Secure all air hose connections, ensuring there are no leaks. 1. Wastegate Actuator 2. Turbocharger Figure 6-20 Proper Setup of Regulated Air for Calibration 8. SLOWLY adjust the air regulator output to 26.1 psi (180 kPa). All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 6-37