8.2 EGR COOLER GAS OUTLET PIPE 8.2.2 Installation of EGR Cooler Gas Outlet Pipe Installation steps are as follows: 1. Apply a light coating of International Product Corporation Rubber Lubricant Emulsion (P-80) to the rubber insert and install the gas outlet pipe into the connector fitting on the EGR control valve. See Figure 8-3. 2. Attach the gas outlet pipe to EGR gas mixer housing using a new metal gasket and two bolts (M8 x 16 mm). Torque the bolts to 25 N·m (18 lb·ft). See Figure 8-3. 3. Position support bracket in place for gas outlet pipe. Install support bracket using three bolts (M8 x 16 mm). Torque the bolts to 25 N·m (18 lb·ft). See Figure 8-3.