EPA07 MBE 4000 SERVICE MANUAL 8.6 EGR COOLER COOLANT RETURN TUBE Exhaust gas cooling is accomplished by the flow of exhaust gases through the EGR cooler tubes. 8.6.1 Removal of EGR Cooler Coolant Return Tube Removal steps are as follows: 1. Drain the engine coolant. 1. Water Pump Inlet Pipe 6. Gasket 2. Connector Pipes 7.Bolts 3. EGR Coolant Return Pipe 8. Washers 4. Bracket 9. Banjo Bolt 5. Bolt Figure 8-12 EGR Cooler Coolant Return Tube 2. Remove the hose connections at the water pump inlet pipe to the water pump. 3. Remove the banjo bolt and two washers from the line on the water pump inlet pipe. Discard the washers. See Figure 8-12. 4.
Remove two bolts securing the water pump inlet pipe and gasket and pull downward and remove EGR cooler coolant return tube. Discard the gasket. See Figure 8-12. 5. Remove the bolt from the clamp attaching the EGR cooler coolant return tube to the turbocharger air inlet elbow and remove tube from the EGR cooler. See Figure 8-12. All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 8-21