Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

8.6 EGR COOLER COOLANT RETURN TUBE 6. Remove the two connector pipes from the return tube. Inspect pipes, if damaged replace. See Figure 8-12. 8.6.2 Installation of EGR Cooler Coolant Return Tube Installation steps are as follows: 1. Coat the two connector pipes with International Product Corporation Rubber Lubricant Emulsion (P-80) and insert them in the EGR cooler coolant return tube. See Figure 8-12. 2. Insert the EGR cooler coolant return tube into the EGR cooler. 3. Insert the water pump inlet pipe into the connector pipe and secure water inlet pipe and gasket to the water pump with two bolts. Torque the bolts to 50 N·m (37 lb·ft). See Figure 8-12. 4.

Install the bolt in the clamp and attach the EGR cooler coolant return tube and bracket to the turbocharger air inlet elbow. Torque the bolts to 35 N·m (26 lb·ft). See Figure 8-12. 5. Install the banjo bolt and two new washers and secure line on the water pump inlet pipe. Torque the banjo bolt to 60–70 N·m (44–52 lb·ft). See Figure 8-12. 6. Install the hose connections at the water pump inlet pipe. Tighten the connections securely. See Figure 8-12. All information subject to change without notice. 8-22 DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION