Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

1.4 CYLINDER BLOCK 1.4.1.2 Measurement of Cylinder Liner Bore Measurement steps are as follows: 1. Set the dial gauge and quick calipers with a dial caliper to the inside diameter of the cylinder liner. Preload the dial gauge to 5 mm (0.20 in.). See Figure 1-19 for set-up and listed in Table 1-9 are specifications. 1. Dial Gauge 3. Dial Caliper 2. Quick Calipers (for internal measurements) Figure 1-19 Setting the Dial Gauge Table 1-9 Cylinder Liner Measurements NOTE: This measurement serves as a baseline against which to measure the actual wear. All information subject to change without notice.

1-26 DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION Where To Measure What To Measure Dimensions: mm (in.) Measuring Point 1: At the area of the O-rings Inside Diameter of the Cylinder Liner, A Class 127.990–127.995 (5.0390–5.0392) Measuring Point 1: At the area of the O-rings Inside Diameter of the Cylinder Liner, B Class 127.995–128.005 (5.0392–5.0396) Measuring Point 1: At the area of the O-rings Inside Diameter of the Cylinder Liner, C Class 128.005–128.010 (5.0396–5.0398) Measuring Point 2: Upper Reversal Point of the First Piston Ring Max.

Wear to Cylinder Liner, Measured Along Axis A and Axis B 0.08 (0.003) At Measuring Point 2, Compare Axis A to Axis B Admissible Wear Out Max.: 0.08 (0.003)