1.4 CYLINDER BLOCK 1. Fuel Gallery Inlet 3. Fuel Gallery Outlet 2. Pressure Gauge Fitting Figure 1-25 Dummy Injector Unit Pumps NOTE: One of the dummy unit pumps has a fitting for pressure gauge installation and it must be installed at the easiest position for gauge installation. 4. Block the fuel gallery inlet and outlet with special plugs from kit (J–45982). See Figure 1-25. 5. Install the pressure gauge assembly (pressure gauge, pressure regulator, and shut off valve) from kit (J–45982) . See Figure 1-26. 6. Connect a compressed air supply to the pressure gauge assembly. 1.

Pressure Gauge on Dummy Unit Pump Figure 1-26 Pressure Gauge Assembly to Dummy Unit Pump EYE INJURY To avoid injury from flying debris when using compressed air, wear adequate eye protection (face shield or safety goggles) and do not exceed 276 kPa (40 psi) air pressure. 7. Pressurize the system with 2 bar (29 psi). Use the pressure regulator to set the pressure. 8. Check for leaks around the dummy unit pumps and inlet/outlet plugs using a soap solution. Eliminate leaks. 9. Close the shut off valve. All information subject to change without notice. 1-32 DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION