EPA07 MBE 4000 SERVICE MANUAL 10. Watch the pressure for 30 seconds. If the pressure holds at 2 bar (29 psi), the fuel gallery is properly sealing. In case of a pressure drop, the engine block should not be reused. 1.4.1.5 Testing of Cylinder Block Cylinder block leak testing steps are as follows: NOTE: This procedure can only be performed with the engine removed from the vehicle and using only the engine block with the cylinder liners installed. 1. Place the engine block with installed cylinder liners on the engine stand. Install the engine on an engine stand. Use OTC engine stand 1750A or equivalent and engine stand adaptor plate J-41576. 2.
Install all six top block cover plates(J–45982–1) from the Head and Block Leak Test kit (J–45982) using the special bolts supplied. See Figure 1-27. 1. Block Cover Plates (6) - part of kit J–45982 3. Pressure Gauge Fitting 2. Water Pump Cover Plate - part of kit J–45982 4. Oil Cooler Cover Plate - part of kit J–45982 Figure 1-27 Block Cover Plates 3. Install the oil cooler/filter housing cover plate, from the kit, on the right hand side of the engine block using supplied hardware. See Figure 1-27. 4. Install the water pump cover plate, from the kit, on the front of the engine using supplied hardware. See Figure 1-27. NOTE:
The water pump cover plate has a fitting for installing the supplied pressure gauge. All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 1-33