MAN — DDC-SVC-MAN-0056 - MBE4000 Safe Operation and Preventative Maintenance Manual

EPA04 MBE 4000 ENGINE OPERATOR'S GUIDE A = On-highway trucks and motor coaches, city transit coaches, pickup and delivery, short trip, and emergency vehicles. B = Industrial, generator set, and other applications Table 24 Nitrite Interval Checks All information subject to change without notice. (Rev. 04/08) 83 DDC-SVC-MAN-0056 04/08 Copyright © 2008 DETROIT DIESEL CORPORATION Coolant Maintenance Interval Action Antifreeze/Water + SCA Inhibitor (DDC Power Cool) A. 20,000 miles (32,000 km) or 3 months B. 500 hours or 3 months Test nitrite concentration with test strip, add SCA or dilute coolant as needed. A. 300,000 miles (480,000 km) or 2 years B.

2 years or 4,000 hours Drain and clean system. Replace with new coolant. Ethylene Glycol/Water + SCA Inhibitor A. 20,000 miles (32,000 km) or 3 months B. 500 hours or 3 months Drain and clean system. Replace with new coolant. A. 300,000 miles (480,000 km) B. 2 years or 4,000 hours Drain and clean system. Replace with new coolant. Ethylene Glycol/Water + OAT Inhibitor A. 300,000 miles (480,000 km) or 2 years B. 5,000 hours Add Power Cool Plus Extender A. 600,000 miles (960,000 km) or 4 years B. 4 years or 10,000 hours Drain and clean system. Replace with new coolant. Water Only + SCA Inhibitor A. 20,000 miles (32,000 km) or 3 months B. 500 hours or 3 months Drain and clean system.

Replace with new coolant. A. 300,000 miles (480,000 km) or 2 years B. 2 years or 4,000 hours Drain and clean system. Replace with new coolant. Water Only + OAT Inhibitor A. 300,000 miles (480,000 km) or 2 years B. 5,000 hours Add Power Cool Plus Extender A. 600,000 miles (960,000 km) or 4 years B. 4 years or 10,000 hours Drain and clean system. Replace with new coolant.