MAN — DDC-SVC-MAN-0056 - MBE4000 Safe Operation and Preventative Maintenance Manual

EPA04 MBE 4000 ENGINE OPERATOR'S GUIDE Coolant Flushing and Changing Flush and change the coolant as follows: To avoid scalding from the expulsion of hot coolant, never remove the cooling system pressure cap while the engine is at operating temperature. Wear adequate protective clothing (face shield, rubber gloves, apron, and boots). Remove the cap slowly to relieve pressure. HOT COOLANT Figure 33 Coolant Drain Plug NOTICE: Do not apply more than 20 psi (140 kPa) air pressure for a radiator flush; more pressure could damage the radiator or heater core. 1. Open the cap on the surge tank slowly, to allow excess pressure to escape. Set the cap aside. 2.

Open the water regulating valve for the heating system. 4. Start radiator flushing by attaching a flushing gun nozzle to the radiator outlet and run water in until the radiator is full. 3. Place a large receptacle underneath the coolant drain plug and open the coolant drain plug on the bottom of the radiator. See Figure 33. NOTE: Make sure the coolant can flow unobstructed into the receptacle. All information subject to change without notice. (Rev. 04/08) 85 DDC-SVC-MAN-0056 04/08 Copyright © 2008 DETROIT DIESEL CORPORATION