Komatsu — HANDLING THE ACCUMULATOR

EXPLANATION OF COMPONENTS OPERATION REFUELLING PUMP Do not bring fire or sparks near the fuel. 1. When the machine is operated on sites with no fuel con- tainer and pump, the machine may be refuelled using the refuelling pump (if fitted) from fuel barrels. The refuelling pump is located next to batteries at the front right hand side of the machine. 2. Place the fuel hose (2), which is stored in tray (3) into the fuel barrel placed next to the machine. 3 2 9JH02623c 3. Switch on refuelling pump using switch (1) on the pump assembly when adding fuel, never let the fuel overflow. This may cause a fires. NOTICE This pump is protected by a fuse (5). If pump fails to function check fuse (10A).

Ensure strainer on hose end is clean. HANDLING THE ACCUMULATOR The accumulator is charged with high-pressure nitrogen gas, so mistaken operation may cause an explo- sion which will lead to serious injury or damage. When handling the accumulator, always do as follows. The pressure in the control circuit cannot be completely removed. When removing the hydraulic equipment, do not stand in a position where the oil spurting out can strike you. Loosen the bolts slowly. Do not disassemble the accumulator. Do not bring it near flame or dispose of it in fire. Do not make holes in it or weld it. Do not hit it, roll it, or subject it to any impact.

When disposing of the accumulator, the gas must be released. Please contact your Komatsu distribu- tor to have this work carried out. 124 WARNING WARNING