Komatsu — ATTACHMENT MOUNTING/DISMOUNTING PROCEDURE

ATTACHMENTS AND OPTIONS MACHINES READY FOR ATTACHMENTS 7. Dismount the attachment by removing the retaining pins (2 pins). Then, mount the bucket. For the bucket mounting procedure, see "REPLACE- MENT AND INVERSION OF BUCKET (PAGE 169)". 8. After the bucket is mounted, check the hydraulic oil level. MOUNTING PROCEDURE 1. Remove the bucket. For bucket dismounting procedure, see "REPLACEMENT AND INVERSION OF BUCKET (PAGE 169)". 2. Place the attachment on a flat place, install pins (A) and (B) to the arm in that order. 3. Turn the starting switch to ON position and push down the safety lock lever to FREE position. 4.

Operate each work equipment control lever and the attachment control pedal back and forth, left and right at full stroke 2 to 3 times to eliminate the internal pressure in the hydraulic circuit. Pin Pin 5. Loosen slowly oil filler cap (F) on top of the hydraulic tank to eliminate the internal pressure in the hydraulic circuit. 6. After confirming low oil temperature, remove the blind plug from the outlet and inlet port respectively. Take care that no dust, mud etc. adheres to the hose mouthpiece portions. If O-ring is damaged, replace it with a new one. Free 7. Turn the rotor of the stop valve connected to the inlet and outlet piping on the arm side face toward the free side. 8.

Confirm that oil level in the hydraulic oil tank is correct, after mounting the attachment. 9JM04428A 293