N6A0058E N6A0060E 5. Set the crankshaft damper pulley TDC mark to the pointer or 45 ° before TDC. Injection Timing Adjustment (4HF1-2 model only) If injection timing is out of the specified range, follow the following procedure for adjustment: 1. Loosen injection pump fixing nuts (1) and bracket bolt (2). 2. Adjust the mounting angle of injection pump: If injection timing is too fast, bring the injection pump closer to the engine. If injection timing is too slow, put the injection pump more distant from the engine. 3. When the dial gage has indicated the specified val- ue, tighten the fixing nuts (1) and bolt (2) to speci- fied torque: Tighten:

Fixing nut to 24 N m (2.4 kg m/17 lb ft) Tighten: Bracket bolt to 48 N m (4.9 kg m/35 lb ft) N6A0059E 6. Set the dial gage to the “0” position. 7. Turn the crankshaft leftwise and rightwise a little and make sure that the needle stays in the “0” po- sition. 8. Turn the crankshaft in the normal direction and read the measuring device’s indication at the 12 ° before TDC position. Notice: As there is no 12 ° mark, set midway between the 11 ° and 13 ° marks. Standard value: 0.5 mm (0.0197 in) N6A0061E