Isuzu — Isuzu N Series Training Manual

Hydraulic Booster PROBLEM POSSIBLE CAUSE CORRECTION Large force pressing on the brake pedal (boosting insufficient) 1. Booster operation insufficient • Large internal leakage • Sticking of the spool valve • Insufficient sliding around the input and output rods • With the engine on, press the brake pedal repeatedly, and confirm the pres- ence of manual operation. With regard to manual operation, turn the engine off, and judge whether the pedal is as stiff and its play is as small as when the pedal is pressed repeated- ly ten times or more. • When there is manual operation, the hydro boost assembly is replaced. Brake dragging 1.

Bad dimensions of the booster • The amount of protrusion of the out- put rod is large • Confirm whether the amount of protru- sion of the output rod (the distance from surface of the master cylinder attach- ment flange to the end of the rod) is no greater than 18.2 mm (0.717 in). • If the above dimension is outside the range, replace the hydro boost assem- bly. 2. Bad pedal circumference attachment dimensions • Clevis position dimension is large • Confirm whether the clevis position di- mension (the distance from surface of the vehicle attachment flange to the center of the clevis center) is in the range 109 ± 1 mm (4.29 ± 0.04 in).

• If the above dimension is outside the range, loosen the lock nut and adjust the clevis position dimension to be in- side the above range. After making this adjustment, be sure to securely tighten the lock nut and to do a stop light switch reconfirmation. 3. Booster return is bad • Input-output rod circumference sticks • Bad spool valve operation • With the engine on, repeatedly press the brake pedal and confirm the pedal return state. • If the pedal does not return, replace the hydro boost assembly as necessary. Oil leakage 1.

Hydro boost assembly external leakage • Leakage from the seal material • If the oil leakage is caused by loose- ness in the piping connections, retight- en the connections. • If there is oil leakage from the connec- tions of the accumulator, replace the af- fected seals of the connections with new seals. • If there is any oil leakage from parts oth- er than the above that are included in the hydro boost assembly, replace the hydro boost assembly or the repair set- ting parts (accumulator).