Isuzu — Isuzu N Series Training Manual

Notice: When the brake pedal is operated after the engine is turned off and the oil pump stops, during a few operations a fluid sound due to the flow of high- pressure oil or a sound of movement by the charge spool may be produced, but this sound is not ab- normal; it merely indicates that boosting by the ac- cumulator (accumulator operation) is proceeding normally. Also, a similar fluid sound is produced during quick operation of the brake pedal even if the engine is on, but this too is normal.

If the pressure of the oil in the accumulator drops with operation of the brake pedal after the engine is turned off or when the engine has been off for a long time, then immediately after the engine is turned on, fluid sound during charge valve opera- tion or switching sound when charging ends will be produced, but this sound is not abnormal; it merely indicates that the accumulator is being normally charged.

Also, a similar charging operation sometimes oc- curs and sound is sometimes produced when the pressure inside the accumulator drops even when the engine is on and charging has ended, due to such causes as rapid operation of the brake pedal, internal leakage that is too slight to affect brake performance, or a change in temperature; this too is normal. When the brake pedal is pressed strongly as far as the booster full load region while the engine is on, sometimes sound is produced by the flow of hy- draulic oil discharged from the oil pump, but this is not abnormal.

Also, pressing the pedal in as far as this booster full load region can cause a significant increase in the oil temperature inside the oil pump and can lead to a failure, so keep the pedal pressed for no longer than 5 seconds. PROBLEM POSSIBLE CAUSE CORRECTION Warning buzzer contin- uously sounds 1. Faulty hydraulic booster assembly • Faulty pressure switch • Leakage inside the charge valve • Confirm that the electric devices (pres- sure switch, relay, buzzer, etc.) are working correctly. • If all are working correctly, pump the brake pedal at least 10 times after turn- ing the engine off to reduce pressure in the hydraulic booster. Start the engine, and release the park- ing brake.

Check to see if the alarm stops within ten seconds (if it does, the electrical devices are working properly). • When testing the electrical devices, al- ways keep your foot on the brake pedal with just enough pressure to prevent the vehicle from moving. If the alarm does not stop, the hydraulic booster assembly may have to be re- placed. Charge operation remains in effect 1. Bad charge valve operation • Bad valve switching operation • Turn the engine on, and without press- ing the brake pedal, check whether any charging sound continues, such as the sound of the fluid. • If it continues and will not stop, replace the hydro boost assembly as neces- sary.