Isuzu — Isuzu N Series Training Manual

Injection Quantity FICD Adjustment 1. Stop the injection pump. 2. Hold speed control lever against idling stopper bolt. 3. Adjust clearance between FICD actuator lever and speed control lever to approx. 1+1 mm (0.0394+0.0394 in). 4. Loosen nut (3) and fully tighten FICD set bolt (2). 5. Apply 53.3 kPa (400 mmHg/7.73 psi) negative pressure to the actuator (1) and set the pump speed at 450 r/min. 6. Gradually loosen set bolt (2) then fix bolt using nut when the rack position is 8.1±0.1 mm (0.3189 ± 0.0039 in). 7. Apply above negative pressure several times and confirm FICD actuator is operating properly and clearance between FICD actuator lever and speed control lever. N6A0966E Legend 1.

Actuator 2. Set bolt 3. Nut 4. Speed control lever 5. FICD actuator lever 6. Tightening torque 5 — 7 N m (0.5 — 0.7 kg m/ 3.7 — 5.2 lb ft) Adjust- ing point Rack position (mm (in)) Pump speed (r/min) Injection q’ty (cm3 /1,000 strokes) Max. variation between cylinders Fixed Pre-stroke at adjust- ment Remarks — 16.1 (0.6339) 1,000 124±1.6 ±4 Rack a1 — a2 (v) Basic Cylinder variation adjust- ment standard Z 8.7±0.5 (0.3425± 0.0197) 585 14±1.5 ±14 Rack c (v) Cylinder variation adjust- ment standard A R1 (16.1 (0.6339)) 1,000 124±1 — Lever a1 — a2 (v) Basic Boost press. kPa (mmHg/ psi) Above 44.0 (330/6.38) B R1+0.45 (0.0177) 1,150 123.5±2 — Lever Measure Boost press.

kPa (mmHg/ psi) Above 44.0 (330/6.38) D* 16.15±0.1 (0.6358± 0.0039) 1,150 — — Lever Measure Boost press. kPa (mmHg/ psi) Above 44.0 (330/6.38) Negative press. kPa (mmHg/psi) 53.3 (400/7.73) D*: Aneroid compensator actuator adjustment point