Aneroid Compensator Actuator Adjustment (In- jection Quantity Decrease) Notice: Set this actuator after adjusting the full rack position. 1. Stop injection pump. 2. Adjust wire nut so full load set lever contacts full load set bolt and aneroid compensator actuator wire is not loose. Then, fix the nut. 3. Apply 53.3 kPa (400 mmHg/7.73 psi) negative pressure to aneroid compensator, set pump speed at 1,150 r/min. N6A0968E Legend 1. Nut 2. Set bolt 3. Full load set lever 4. Full load set bolt Rack Sensor Adjustment 1.
Before removing rack position measuring device, apply at least 44.0 kPa (330 mmHg/6.38 psi) boost pressure and confirm rack position is R1 = 16.1 mm and fuel injection quantity is 124 ± 1 mm 3 /st at N = 1,000 r/min. N6A0967E Legend 1. Rack position (mm) 2. Pump speed (r/min) 3. Stroke 4. Injection quantity decrease adjustment point 4. Apply at least 44.0 kPa (330 mmHg/6.38 psi) boost pressure to the boost compensator. 5. After operating full load set lever, adjust aneroid compensator set bolt so control rack position is 16.15±0.1 mm (0.6358 ± 0.0039 in) and fuel injec- tion quantity is as specified. Then, fix the set bolt. N6A0969E Legend 1. Rack position (mm) 2. Pump speed (r/min) 2.
Remove the rack position measuring device. 3. Attach the rack sensor core to the control rack.