At this time, hold control rack using a spanner (to prevent the rack from bending). Specified torque: 3.4 — 4.9 N m (0.35 — 0.5 kg m/2.5 — 3.6 lb ft) 4. While pulling stop lever, install rack sensor to rack sensor core. 5. Tighten the two flnge fixing screws. Specified torque: 6.9 — 8.8 N m (0.7 — 0.9 kg m/5.1 — 6.5 lb ft)) 6. Connect the rack sensor wire harness to constant voltage power supply and digital voltmeter. 7. Turn constant voltage power supply power switch ON and set it to DC 5 ± 0.01V. 8. Apply at least 44.0 kPa (330 mmHg/6.38 psi) boost pressure, set pump speed at N = 1,000 r/min, and hold speed control lever against the full speed stopper bolt. 9.
Confirm the rack sensor output voltage from the digital voltmeter. (Vist = 2.77 ± 0.28V) 10. Confirm that the voltage changes when the speed control lever is moved to the idle and full sides. N6A0970E Legend 1. Sensor output voltage (V) 2. Rack position (mm)