3. Attach the end of one jumper cable to the positive terminal of the booster battery. Attach the other end of the same cable to the pos- itive terminal of the discharged battery. Do not allow the vehicles to touch each other. This will cause a ground connection, effectively neutralizing the charging procedure. Be sure that the booster battery has a 12 volt rat- ing. 4. Attach one end of the remaining cable to the nega- tive terminal of the booster battery. Attach the other end of the same cable to a solid engine ground (such as the A/C compressor brack- et or the generator mounting bracket) of the vehicle with the discharged battery.
This ground connection must be at least 450 mm (18 in) from the battery of the vehicle whose battery is being charged. Be sure to first disconnect the negative cable from the vehicle with the discharged battery. Removal 1. Negative cable 2. Positive cable 3. Retainer screw and rods 4. Retainer 5. Battery NEVER ATTACH THE END OF THE JUMPER CABLE DIRECTLY TO THE NEGATIVE TERMINAL OF THE DEAD BATTERY. 5. Start the engine of the vehicle with the good bat- tery. Make sure that all unnecessary electrical accesso- ries have been turned “OFF”. 6. Start the engine of the vehicle with the dead bat- tery. 7. To remove the jumper cables, follow the above di- rections in the reverse order.
N6A0984E Installation To install the battery, follow the removal procedure in the reverse order, noting the following points: 1. Make sure that the rod is hooked on the body side. Main Data and Specifications WWaArRnNinIgN:G: Model (JIS) 65D23R 75D23R 80D26R 115E41R DELCO 31-750 Voltage (V) 12 12 12 12 12 Cold-Cranking Performance (Amp) 520 356 750 Reserve Capacity (Min.) 180 133 160