5 Control Heads Single Lever CAN Bus Control Head Calibration for Single Function Controls CH4400 or CH5600 (see page 5:29) This calibration procedure is for single lever (both shift and throttle on a lever) controls with Software Rev. 1.9 or higher. Earlier units should be updated. Controls are factory calibrated, but this procedure is supplied in the event you need to restrict CH675XX, CH676XX, CH2210, or CH1900 lever travel. Single Lever - Single Engine Controls With the system OFF (no power on the CAN Bus) press and hold the Neutral button on the control head and turn the power ON. The Neutral lamp will blink. Move the lever to the FULL FORWARD position and press the SELECT button.

The select lamp will turn on. Move the lever to the FORWARD IDLE position. The neutral lamp will blink. Press the SELECT button. The select lamp will turn on. Move the lever to the NEUTRAL position. The neutral lamp will blink. Press the SELECT button. The select lamp will turn on. Move the lever to the REVERSE IDLE position. The neutral lamp will blink. Press the SELECT button. The select lamp will turn on. Move the lever to the FULL REVERSE position. The neutral lamp will blink. Press the SELECT button. The select and neutral lamps will both blink indicating the process is complete. Turn the power OFF to exit the calibration process. © 2011 Yanmar Marine International • Rev.

2.0 5:22 Yanmar Electronic Control Systems Technical Manual