8 Networks Cables NOTICE The cables must not be cut or spliced. Replace worn or frayed cables. When securing the cables and especially when tying down a number of direct connected “Ts” never pull them down so tight as to cause strain or put a curve in the “Ts” as this may cause a failure. The cabling that is used conforms to the DeviceNet standard and was developed for Industrial applications. In general the cables are molded and the connection area is sealed with o-ring gaskets to provide a good seal from the environment. The cables are available in a variety of lengths. When installing a NMEA 2000 ® CAN Bus system there are several things to keep in mind:
The cable ends are male and female. To avoid a mismatch it is best to work from one end toward the other. If you must work from both ends toward the middle assure that the mating point will be a male/female connection. It is wise to plan for expansion. With so many new NMEA 2000 ® products entering the market and the ability to connect on to the bus for testing it is sometimes wise to use two cables where one would suffice. The connection of the two cables can later be separated so additional “Ts” can be inserted to add another product or test equipment. On 24 volt systems, a DC to DC converter or separate 12 volt battery is required. Powering the Bus The CAN Bus requires DC power.
The voltage range is 9 to 16 volts. The power may be supplied by one or more of the products on the Data Bus or from a separate source. Most equipment manufacturers strongly recommends that at least two independent sources are used to supply the data bus power. CAN Bus Power The CAN Bus is used to supply power to all the items that are connected on the bus. For items drawing less than one amp, not having any other power connection, or another path back to ground the entire power for the item may be pulled from the CAN Bus. This requires the CAN Bus to have adequate sources of power. © 2011 Yanmar Marine International • Rev. 2.0 8:10 Yanmar Electronic Control Systems Technical Manual