Yanmar — Yanmar Electronic Control System Technical Manual for Classic, BY2, 6LY3, 6CX, and SY GEN III Series Engines

8 Networks Boats with One Helm Station Caution: If the distance exceeds the length in the tables A, B, and C below, add CAN Bus power at the helm. This assumes that the power source resides in the engine room.

A) Single Engine Installations Units at Helm X max feet Control Head and one Digital Display 150 Control Head, Digital Display, Gauges 55 B) Dual Engine Installations Control Head and two Digital Displays 85 Control Head, Digital Display, Gauges 30 C) Triple Engine Installations Control Head and three Digital Displays 40 Control Head, Digital Display, Gauges 12 Adding CAN Bus power is typically accomplished by running a pair of wires (plus and minus) from the battery or an auxiliary power feed to the location where the power is to be put on the CAN Bus. The connection should have a circuit breaker or fuse and a diode in the positive line to stop any back feed. Reminder:

This extra feed should be switched since it will keep the CAN Bus active. Yanmar and Teleflex offer a cable for this purpose; the part number CMS-1. Boats with Two or More Helm Stations Additional information about multi-engine installations may be found in manual MANINYM03. In these cases it matters how the source of CAN Bus power is located on the CAN Bus. The CAN Bus power source may be located near the middle of the CAN Bus or near one end of the CAN Bus. How the CAN Bus was run has a significant impact as you will see in the information that follows. Case 1 © 2011 Yanmar Marine International • Rev. 2.0 8:12 Yanmar Electronic Control Systems Technical Manual