Yanmar — Yanmar Electronic Control System Technical Manual for Classic, BY2, 6LY3, 6CX, and SY GEN III Series Engines

8 Networks If a distance in the case one table is exceeded add power at all helms that exceed the distance. Case 1 - Single Engine Installations with 2 Helm Station Units at Helm X max feet Y max feet Control Head, Digital Display, Gauges 55 55 Control Head and one Digital Display 150 150 Case 1 - Dual Engine Installations with 1 Helm Station Control Head and two Digital Displays 80 80 Control Head, Digital Display, Gauges 25 25 Case 1 - Triple Engine Installations with 1 Helm Station Control Head and three Digital Displays 40 40 Control Head, Digital Display, Gauges 12 12 Case 2 Note: Add X plus Y and use this number in the table.

Case 2 - Single Engine Installations with 2 Helm Stations Units at Helm X + Y max feet Control Head and one Digital Display 75 - Add power at the first helm above this number Control Head, Digital Display, Gauges 25 - Add power at the first helm above this number andcadd power at the second helm if Y exceeds 55 feet. Case 2 - Dual Engine Installations with 2 Helm Stations Control Head and two Digital Displays 40 - Add power at the first helm above this number Control Head, Digital Display, Gauges 12 - Add power at the first helm above this number and add power at the second helm if Y exceeds 40 feet.

Case 2 - Triple Engine Installations with 2 Helm Stations Control Head and three Digital Displays 20 - Add power at the first helm above this number and add power at the second helm if Y exceeds 20 feet Control Head, Digital Display, Gauges Always add CAN Bus power at both helms. © 2011 Yanmar Marine International • Rev. 2.0 Yanmar Electronic Control Systems Technical Manual 8:13