8 Networks Load Equivalency Numbers (LENs) The following information is supplied for those who need to calculate voltage drops in complex networks: The lowest voltage permitted at any node is 9.00 volts. Below this level equipment will start to shut down. Good practice is to have some safety factor. If other manufacturers’ devices are used on the network, check their voltage requirements. The power wires (red and black) in the CAN Bus cable are 22 AWG. The resistance of 22 AWG wire is 16.14 ohms per 1000 feet. Remember the plus and minus both must be considered. A 20 foot long cable adds 40 feet of wire to the circuit. The following are the typical loads presented by various Yanmar products.

One load equivalency unit is 50 mAmps (0.05 amps). The sum of the LENs multiplied by 0.05 is the DC current consumption of the network in amps. Typlical current draw is significantly less than the max numbers shown in the table and usually less than half of those values. Operation Some of this information is the same as covered under “Network Basics” (previous), but explained with more technical details. Startup and Addressing The NMEA 2000 ® CAN Bus is a multi-master system. Each unit connected to the CAN Bus can use the bus for a period of time within the rules of the protocol. For any multi device network to operate each unit connected to the bus must have a unique address.

In many systems these addresses must be set by a technician before the system will operate. When a NMEA 2000 ® network or a unit is “powered on” all units monitor the “claims” being made. If another device has the same address, the arbitration process begins. Each device on the network starts with a built in default address and then checks for other devices on the bus with the same address. If it finds another unit with an identical address an arbitration process occurs between the devices with identical addresses and unique addresses are assigned. This process is quite fast and is usually complete in about 100 milliseconds (one tenth of a second) for the entire network.

When an additional device is added or removed from a “powered on” operating CAN Bus the same process occurs. During the process each individual items takes a safe course of action so no network upset occurs. Understanding - It is quite possible that, on the same network, the addresses of the units may be different each time the network is turned on. They may also be altered by the addition or removal of a device from an active network. These address changes have no impact on the operation of the network. © 2011 Yanmar Marine International • Rev.

2.0 8:14 Yanmar Electronic Control Systems Technical Manual Product Current NMEA 2000® Load Equivalency Number • Control Head 200 mAmp 4 • Typical Interface 200 mAmp 4 • Digital Display (monochrome) 400 mAmp 8 • Gauges 1000 mAmp 20 • Actuators 200 mAmp 4