15 Troubleshooting Initial Review Below is a list of the initial indicators that need to be reviewed and the normal condition for each item. Based on the above results you can start to draw some conclusions. The next table lists observations that indicate a system power problem. Subsequent tables cover other problems. © 2011 Yanmar Marine International • Rev. 2.0 Yanmar Electronic Control Systems Technical Manual 15:3 TABLE 1 - Normal Operation Observe Expectation Comment Battery Voltage Use any indicator including a separate meter at battery. 12 VDC on most systems and should rise 1.5 to 2 volts when the engine is running. Low voltage is the most frequent cause of a control system problem.
Control Head • Single Station • Multiple Stations • Select lamp ON. Neutral Lamp(s) ON. • Green Select Lamps blinking on all stations. • On and levers positioned in Neutral. • Selected Head, green ON. All other Heads, green OFF. i5601E Display ON, displays active engine data. 0 RPM (not dashes) with key ON, engine not running; other data present. Round Gauges Reading. Needles move when turned on. Engine Interfaces BY2 • No indicators. 6LY3, 6CX • Center LED • Right LED • Left LED SY GEN III • i8350 • NMEA • J1939 • No indicators. • Blinking at a regular rate. • Blinking. • Blinking. • Blue. Blinking at a regular rate. • Green. Blinking. • Yellow. Blinking. • Processor operating.
• NMEA 2000® operating. • J1939 Engine Communications operating. • Processor operating. • NMEA 2000® operating. • J1939 Engine Communications running. Key Switch Panel • BY2 • 6LY3, 6CX & SY GEN III • Check engine lamp. • Check Sub Throttle lamp. • Normally OFF. • Normally OFF. Engine Relays or Injectors Some noise when turned on is normal.