侍# Some fault codes are not applied to this machine. 3-60 Fault code (Hex) Meaning of the fault code possible reason for fault detection Reaction of the TCU Possible steps to repair 34 S.C. to battery voltage or O.C. at turbine speed input TCU measures a voltage higher than 7.00V at speed input pin  Cable is defective and is contacted to vehicle battery voltage ÂCable has no connection to TCU ÂSpeed sensor has an internal defect ÂConnector pin is contacted to battery voltage or has no contact OP mode : Substitute clutch control If a failure is existing at output speed, TCU shifts to neutral OP mode :

Limp home 余 Check the cable from TCU to the sensor 余 Check the connectors 余 Check the speed sensor 35 S.C. to ground at turbine speed input TCU measures a voltage less than 0.45V at speed input pin  Cable/connector is defective and is contacted to vehicle ground ÂSpeed sensor has an internal defect OP mode : Substitute clutch control If a failure is existing at output speed, TCU shifts to neutral OP mode :

Limp home 余 Check the cable from TCU to the sensor 余 Check the connectors 余 Check the speed sensor ö This fault is reset after power up of TCU 36 Logical error at turbine speed input TCU measures a turbine speed over a threshold and at the next moment the measured speed is zero  Cable/connector is defective and has bad contact ÂSpeed sensor has an internal defect ÂSensor gap has the wrong size OP mode : Substitute clutch control If a failure is existing at output speed, TCU shifts to neutral OP mode : Limp home 余 Check the cable from TCU to the sensor 余 Check the connectors 余 Check the speed sensor 余 Check the sensor gap 37 S.C. to battery voltage or O.C.

at internal speed input TCU measures a voltage higher than 7.00V at speed input pin  Cable is defective and is contacted to vehicle battery voltage ÂCable has no connection to TCU ÂSpeed sensor has an internal defect ÂConnector pin is contacted to battery voltage or has no contact OP mode : Substitute clutch control 余 Check the cable from TCU to the sensor 余 Check the connectors 余 Check the speed sensor 38 S.C. to ground at turbine speed input TCU measures a voltage less than 0.45V at speed input pin  Cable/connector is defective and is contacted to vehicle ground ÂSpeed sensor has an internal defect OP mode :

Substitute clutch control 余 Check the cable from TCU to the sensor 余 Check the connectors 余 Check the speed sensor 39 Logical error at internal speed input TCU measures a internal speed over a threshold and at the next moment the measured speed is zero  Cable/connector is defective and has bad contact ÂSpeed sensor has an internal defect ÂSensor gap has the wrong size OP mode : Substitute clutch control 余 Check the cable from TCU to the sensor 余 Check the connectors 余 Check the speed sensor 余 Check the sensor gap ö This fault is reset after power up of TCU 3A S.C. to battery voltage or O.C.

at output speed input TCU measures a voltage higher than 12.5V at speed input pin  Cable is defective and is contacted to battery voltage ÂCable has no connection to TCU ÂSpeed sensor has an internal defect ÂConnector pin is contacted to battery voltage or has no contact Special mode for gear selection OP mode : S u b s t i t u t e clutch control If a failure is existing at turbine speed, TCU shifts to neutral OP mode : Limp home 余 Check the cable from TCU to the sensor 余 Check the connectors 余 Check the speed sensor