Kaiyi — Kaiyi Power Train System Technical Manual

Some fault codes are not applied to this machine. 3-65 Fault code (Hex) Meaning of the fault code possible reason for fault detection Reaction of the TCU Possible steps to repair 7F O.C. at engine derating device TCU detected a wrong voltage at the output pin, that looks like a O.C. for this output pin Cable is defective and has no connection to TCU Engine derating device has an internal defect Connector has no connection to TCU No reaction OP mode : Normal  Check the cable from TCU to the engine derating device  Check the connectors from engine derating device to TCU  Check the resistance* of engine derating device * See page 3-74 81 S.C.

to battery voltage at clutch K4 The measured resistance value of the valve is out of limit, the voltage at K4 valve is too high Cable/connector is defective and has contact to battery voltage Cable/connector is defective and has contact to another regulator output of the TCU Regulator has an internal defect TCU shifts to neutral OP mode : Limp home If failure at another clutch is pending TCU shifts to neutral OP mode : TCU shutdown  Check the cable from TCU to the gearbox  Check the connectors from gearbox to TCU  Check the regulator resistance*  Check internal wire harness of the gearbox * See page 3-74 82 S.C.

to ground at clutch K4 The measured resistance value of the valve is out of limit, the voltage at K4 valve is too low Cable/connector is defective and has contact to vehicle ground Regulator has an internal defect TCU shifts to neutral OP mode : Limp home If failure at another clutch is pending TCU shifts to neutral OP mode : TCU shutdown  Check the cable from TCU to the engine derating device  Check the connectors from gearbox to TCU  Check the regulator resistance*  Check internal wire harness of the gearbox * See page 3-74 83 O.C.

at clutch K4 The measured resistance value of the valve is out of limit Cable/connector is defective and has contact to TCU Regulator has an internal defect TCU shifts to neutral OP mode : Limp home If failure at another clutch is pending TCU shifts to neutral OP mode : TCU shutdown  Check the cable from TCU to the gearbox  Check the connectors from gearbox to TCU  Check the regulator resistance*  Check internal wire harness of the gearbox * See page 3-74 84 S.C.

to battery voltage at clutch KV The measured resistance value of the valve is out of limit, the voltage at KV valve is too high Cable/connector is defective and has contact to battery voltage Cable/connector is defective and has contact to another regulator output of the TCU Regulator has an internal defect TCU shifts to neutral OP mode : Limp home If failure at another clutch is pending TCU shifts to neutral OP mode : TCU shutdown  Check the cable from TCU to the gearbox  Check the connectors from gearbox to TCU  Check the regulator resistance*  Check internal wire harness of the gearbox * See page 3-74 85 S.C.

to ground at clutch KV The measured resistance value of the valve is out of limit, the voltage at KV valve is too low Cable/connector is defective and has contact to vehicle ground Regulator has an internal defect TCU shifts to neutral OP mode : Limp home If failure at another clutch is pending TCU shifts to neutral OP mode : TCU shutdown  Check the cable from TCU to the gearbox  Check the connectors from gearbox to TCU  Check the regulator resistance*  Check internal wire harness of the gearbox * See page 3-74