Kaiyi — Kaiyi Power Train System Technical Manual

侍# Some fault codes are not applied to this machine. 3-69 Fault code (Hex) Meaning of the fault code possible reason for fault detection Reaction of the TCU Possible steps to repair A4 S.C. to ground at warning signal output TCU detected a wrong voltage at the output pin, that looks like a S.C. to vehicle ground ÂCable is defective and is contacted to vehicle ground ÂWarning device has an internal defect ÂConnector pin is contacted to vehicle ground No reaction OP mode : Normal 余 Check the cable from TCU to the warning device 余 Check the connectors from warning device to TCU 余 Check the resistance* of warning device * See page 3-74 A5 O.C.

voltage at warning signal output TCU detected a wrong voltage at the output pin, that looks like a O.C. for this output pin ÂCable is defective and has no connection to TCU ÂWarning device has an internal defect ÂConnector has no connection to TCU No reaction OP mode : Normal 余 Check the cable from TCU to the warning device 余 Check the connectors from warning device to TCU 余 Check the resistance* of warning device * See page 3-74 A6 S.C. to battery voltage at warning signal output TCU detected a wrong voltage at the output pin, that looks like a S.C.

to battery voltage ÂCable is defective and has is contacted to battery voltage ÂWarning device has an internal defect ÂConnector pin is contacted to battery voltage No reaction OP mode : Normal 余 Check the cable from TCU to the warning device 余 Check the connectors from warning device to TCU 余 Check the resistance* of warning device * See page 3-74 B1 Slippage at clutch K1 TCU calculates a differential speed at closed clutch K1.

If this calculated value is out of range, TCU interprets this as slipping clutch ÂLow pressure at clutch K1 ÂLow main pressure ÂWrong signal at internal speed sensor ÂWrong signal at output speed sensor ÂWrong size of the sensor gap ÂClutch is defective TCU shifts to neutral OP mode : Limp home If failure at another clutch is pending TCU shifts to neutral OP mode :

TCU shutdown 余 Check pressure at clutch K1 余 Check main pressure in the system 余 Check sensor gap at internal speed sensor 余 Check sensor gap at output speed sensor 余 Check signal at internal speed sensor 余 Check signal at output speed sensor 余 Replace clutch B2 Slippage at clutch K2 TCU calculates a differential speed at closed clutch K2. If this calculated value is out of range, TCU interprets this as slipping clutch ÂLow pressure at clutch K2 ÂLow main pressure ÂWrong signal at internal speed sensor ÂWrong signal at output speed sensor ÂWrong size of the sensor gap ÂClutch is defective TCU shifts to neutral OP mode :

Limp home If failure at another clutch is pending TCU shifts to neutral OP mode : TCU shutdown 余 Check pressure at clutch K2 Check main pressure in the system 余 Check sensor gap at internal speed sensor 余 Check sensor gap at output speed sensor 余 Check signal at internal speed sensor 余 Check signal at output speed sensor 余 Replace clutch