24. SERVICE PROCEDURE 7. Stop running water through the system, then stop the engine. 8. Open drain valve 0 at the bottom of the radiator and drain plug @I on the side face of the cylinder block to drain the water. 9. After draining the water, tighten drain valve 0 and drain plug 0, and fill the radiator with water. 10. In areas where the water is hard, pour the anti-corrosive agent KI-2 solution to the radiator. For details, see “24.7.7 ADD ANTI-CORROSIVE AGENT TO COOLING SYSTEM”. 11. Add antifreeze solution to the specified density. For details, see “Table of mixing rate of water and anti- freeze”. 12.
To remove the air in the cooling water, run for five minutes at low idling, then for another five minutes at high idling. (When doing this, leave the radiator cap off.) 13. Stop the engine, wait for 3 minutes, add city water until the water level reaches near the water filler port, then tighten the cap. 3-28