Komatsu — 24.2 WHEN REQUIRED

24. SERVICE PROCEDURE 24.2.2 CHECK, CLEAN AND REPLACE AIR CLEANER ELEMENT l Never clean or replace the air cleaner element with l When using pressure air to clean the element wear safety glasses or goggles to protect the eyes. Checking Whenever air cleaner clogged warning lamp 0 lights up, clean the air cleaner outer element. Cleaning or replacing outer element 1. Loosen clip 0, remove dust cup 0 and the outer element. 2. Clean the air cleaner body interior and the dust cup. 3. Direct dry compressd air (less than 7 kg/cm*) to the ele- ment from inside along its folds, then direct it from out- side along its folds and again from inside. 1) Remove one seal from the outer element.

The number of times the outer element has been cleaned can be seen by the number of removed seals. Replace the outer element which has been cleaned 6 times repeatedly or used throughout a year. Replace the inner element at the same time. Replace the element when the air cleaner clogged warning lamp lights up soon after installing the cleaned element even though it has not been cleaned 6 times. Check inner element mounting nuts for looseness and, if necessary, retighten. Replace seal washer @ or wing nut 0 with new parts if they are broken. Remove evacuator valve 0 and clean with compressed air. After cleaning, install it. 2) 3) 4) 5) 6) 3-29