JCB — 74.pdf (p.74)

Section E - Hydraulics Circuit Descriptions Slew Circuit Slew Circuit For schematic, K Fig 18. ( T E-51) . Slew over Dipper Priority (A) Circuit description is for swing left. This is a non-selectable function automatically carried out within the main control valve 14 when slew and dipper are used together. Servo pressure from the hand controller 50 enters the Servo shuttle valve 46 at port A2 and is distributed to: 1 Port C7 to port A on 8 station solenoid valve 60 . When slew is selected a signal is sent from the servo shuttle valve 46 via port C8 to the main control valve 14 at port Pc3. This selects slew over dipper priority valve B and limits the flow to the dipper from pump A2 only.

This makes it possible to have maximum slew torque with high slew pressure when the dipper is used at the same time. 2 Port C8 to port Pc3 in main control valve to the slew over dipper priority spool SDV. 3 Port S1 to the slew pressure switch 45 . 4 Port B2 via the slew shut off solenoid 44 to the slew spool at port Pa3 on the main control valve 14 to move spool across. When the pressure switch 45 closes, a signal is sent from the ECU1 to energise CT1 on the 8 station solenoid valve 60 . This allows 40 bar (580 lb/in 2 ) to cross the solenoid then cross the shuttle CT10 and the slew lock solenoid CT3 to release the slew brake.

When the slew pressure switch 45 opens, the solenoid remains energised for 5 seconds to allow the slew to come to a standstill before the brake is applied. If the pressure switch fails, there is an override device fitted. Servo pressure from the hand controller 50 passes through the shuttle valve 46 and exits at C7. This signal is sent to the 8 station solenoid valve 60 to port A, crosses the shuttle CT10 and the slew lock solenoid CT3 and releases the slew brake. Note: When the override is in operation, the slew may become very harsh. Flow from pump 2 travels through the neutral gallery to the slew spool.

The flow is restricted allowing reduced pressure at port ps1 which is sensed at pm2 of pump 2 allowing the pump to come to full flow. The flow passes through into the parallel working passage to the slew spool. The flow is then directed via port A3 to the slew motor 1 . Exhaust oil enters the main control valve 14 at B3 through the slew spool to the tank line. E-50 E-50 9803/9880-3