Section 3 - Maintenance Routine Maintenance Electrical System Electrical System Battery At the end of a working cycle or if the machine is being left unattended or if carrying out maintenance, the battery must be isolated. Before attempting to start the engine or use the machine electrics the battery isolator key must be fitted and switched on. Fig 14. 4 Disconnect the batteries from the machine electrics. a Turn the battery isolator key A in a counter- clockwise direction B and remove. Note: If the batteries are isolated, the radio may loose its preset memories. b Keep the key in a safe place and available for when the machine is next required. 1 Make the machine safe.
Refer to Prepare the Machine for Maintenance . 2 Locate the battery isolator in the battery bay. To connect the batteries insert the key A and turn in a clockwise direction C . 3 To allow the engine ECU to shutdown correctly, you must wait 30 seconds ( X ) before you isolate the battery. The 30 second period starts when you switch OFF the machine ignition. 3-39 3-39 9803/JSM-0412 Note: Before commencing work on the batteries you must read the following procedure in Health and Safety; K Battery ( T 3-5). Note: If a battery requires replacement then both batteries must be replaced.
Battery Isolator T3-101 To disconnect the batteries from the machine electrics a battery isolator has been fitted. Important: DO NOT use the battery isolator when the engine is running, this may result in damage to the machine electrics. !M CAUTION Before carrying out arc welding on the machine, disconnect the battery and alternator to protect the circuits and components. The battery must still be disconnected even if a battery isolator is fitted. INT-3-1-13