Section B - Body and Framework Service Procedures Air Conditioning Compressor Air Conditioning Compressor Do not operate the air conditioning system when there is no refrigerant in the system, otherwise the compressor will be damaged. Fig 10. Replacement 4-3-4-4 Replacement is the reverse of the removal procedure. !M WARNING Note: If the machine was not previously fitted with Air conditioning a new engine mounting bracket 2 must be fitted. Do not carry out welding operations close to the air conditioning refrigerant circuit. A poisonous gas is produced when refrigerant comes into contact with naked flames. Do not smoke or allow naked flames close to the refrigerant circuit.

The Air Conditioning system should be recharged. BF-1-9 For belt tension K Technical Data ( T B-1) 1 Label and remove hoses 10-A from the compressor 10-B . 2 Loosen the compressor drive belt tensioner 10-C and remove drive belt 10-D . 3 Disconnect the wiring harness from the compressor at 10-E . 4 Remove the four capscrews 10-G and remove the compressor from the mounting bracket 10-F . B-25 B-25 9803/9880-3 Removal Note: Before removing any of the hoses from the compressor, the system must be discharged. !M WARNING The air conditioning system is a closed loop system and contains pressurised refrigerant.

No part of the system should be disconnected until the system has been discharged by a refrigeration engineer or a suitably trained person. You can be severely frostbitten or injured by escaping refrigerant. 4-3-4-1 2 _ !M CAUTION F A G D E B C