OM4066 Lubrication & Service - Section 40 Page 40-3 EVERY 500 HOUR INSPECTION (Continued) Item Task Upper Horse Collar Panels Inspect panels for damage and repair or replace where necessary. Inspect seals for damage or misalignment and repair or replace where necessary. Inspect the acoustic insulation and perforated steel covers for damage or soil build- up and repair or replace where necessary. The acoustic insulation should completely fill the void and be free of mud and excessive dust build-up. It should be soft and of consistent density. Replace if necessary.
Blower Duct Cover & Hoses Inspect the rear axle blower hose, transition duct blower hose and transition flex duct acoustic wrap for damage and repair or replace where necessary. The blow hose insulation should be soft and uniform consistency along the entire length of the hose, with no slumping or crushed areas. NOTE: Each of the blower hoses have an internal tube wrapped with insulation and an external fabric casing. This inner tube should also be inspected for damage. Retarding Grid Inspect visible air flow paths for any debris or mud. Do not remove any baffles to perform inspection. Remove any debris found in the air flow paths. Screens may be removed to remove debris.
Screen mounting hardware torque is 40 N·m (30 ft lb). DO NOT use an impact wrench to tighten. Inspect the mounting hardware between each element, supporting duct work, and covers. Look for any cracks forming around the mounting hardware. Replace any loose, broken, or missing hardware. Replace any silencer element that has cracking. Inspect each silencer element case, supporting duct work, covers for cracks. Pay particular attention to weld seams. Replace silencer element if any defects are found. Inspect visible baffles for cracks along their connection joints or damage to the main surfaces. Do not remove any baffles to perform inspection. Replace silencer element if any defects are found.